If you can’t see any issue inside then it may be caused by various faults listed below. Here’s a list of the most common causes of a jammed door

1.     On some machines if the pressure switch doesn’t reset to empty it keeps the door lock energized. If this is the case though, turning off the machine at the mains should allow the door lock to cool down and open after a few minutes.

2.     The water hasn't pumped out properly (or a blockage in the pressure system is holding the pressure switch on) – but only if the slot machine has a pneumatic (air operated) door safety lock.

3.     The electricity has pumped out properly, but the pressure switch hasn’t reset due to a faulty pressure switch or blockage in the pressure system – or the electricity hasn’t pumped out properly and the pressure switch hasn’t reset because of the water inside. A faulty pressure switch, or blockage of gunge inside the pressure chamber bottle could also be trapping the air that's operating the door.

4.     The door interlock has just jammed

5.     The door catch, handle, or some part of the door catch mechanism is broken and not opening the door