DESCRIPTION

UL 5107, and 5128 wires have glass-reinforced mica tape insulation and a braided fiberglass jacket for enhanced abrasion resistance. They meet all UL requirements for appliance lead wire, and are also available with CSA certification.

SPECIFICATIONS

AWG
10
Conductor
27% nickel-coated copper
Conductor Diameter (Nominal) (in)
0.110 (2.79)
Insulation
Multiple layers of mica / glass composite tape
Insulation Diameter (Nominal) (in)
0.187 (4.75)
Jacket Material
Glass braid with PTFE high-temperature saturant (or silicone high-temperature saturant)
Max. Conductor Resistance
1.60 (5.25)
Max. Working Voltage
300V (UL 5128)
Strading
37/26
Temperature Rating
450° C, 250° C with optional nickel-plated copper conductor
Weight (lb)
49.8 (74.1)